American Association for Cancer Research
Browse
10780432ccr150314-sup-145156_2_supp_2991468_nfrf4t.png (50.08 kB)

Supplemental Figure S1 from Targeting Acidity in Pancreatic Adenocarcinoma: Multispectral Optoacoustic Tomography Detects pH-Low Insertion Peptide Probes In Vivo

Download (50.08 kB)
figure
posted on 2023-03-31, 19:05 authored by Charles W. Kimbrough, Anil Khanal, Matthew Zeiderman, Bigya R. Khanal, Neal C. Burton, Kelly M. McMasters, Selwyn M. Vickers, William E. Grizzle, Lacey R. McNally

Supplemental Figure S1: (A) Uv-Vis absorbance of K7-750 and V7-750 probes at 40 μM peptide concentration. Absorbance peak at 280 nm shows the peptide peak, while absorbance peak at 750 nm shows the dye peak. (B) Normalized absorbance of V7-750, K7-750, deoxy-hemoglobin, and oxy-hemoglobin. These spectra were utilized for spectral unmixing of images acquired using MSOT imaging.

History

ARTICLE ABSTRACT

Background: pH-low insertion peptides (pHLIP) can serve as a targeting moiety that enables pH-sensitive probes to detect solid tumors. Using these probes in conjunction with multispectral optoacoustic tomography (MSOT) is a promising approach to improve imaging for pancreatic cancer.Methods: A pH-sensitive pHLIP (V7) was conjugated to 750 NIR fluorescent dye and evaluated as a targeted probe for pancreatic adenocarcinoma. The pH-insensitive K7 pHLIP served as an untargeted control. Probe binding was assessed in vitro at pH 7.4, 6.8, and 6.6 using human pancreatic cell lines S2VP10 and S2013. Using MSOT, semiquantitative probe accumulation was then assessed in vivo with a murine orthotopic pancreatic adenocarcinoma model.Results: In vitro, the V7-750 probe demonstrated significantly higher fluorescence at pH 6.6 compared with pH 7.4 (S2VP10, P = 0.0119; S2013, P = 0.0160), whereas no difference was observed with the K7-750 control (S2VP10, P = 0.8783; S2013, P = 0.921). In the in vivo S2VP10 model, V7-750 probe resulted in 782.5 MSOT a.u. signal compared with 5.3 MSOT a.u. in K7-750 control in tumor (P = 0.0001). Similarly, V7-750 probe signal was 578.3 MSOT a.u. in the S2013 model compared with K7-750 signal at 5.1 MSOT a.u. (P = 0.0005). There was minimal off-target accumulation of the V7-750 probe within the liver or kidney, and probe distribution was confirmed with ex vivo imaging.Conclusions: Compared with pH-insensitive controls, V7-750 pH-sensitive probe specifically targets pancreatic adenocarcinoma and has minimal off-target accumulation. The noninvasive detection of pH-targeted probes by means of MSOT represents a promising modality to improve the detection and monitoring of pancreatic cancer. Clin Cancer Res; 21(20); 4576–85. ©2015 AACR.See related commentary by Reshetnyak, p. 4502

Usage metrics

    Clinical Cancer Research

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC